![]() ![]() V/I CONVERTER: V/I conversion the input voltage range is: 0 to 8 Vdc, and the output current range is: 4 to 20 mA I/V CONVERTER: I/V conversion the input current range is: 4 to 20 mA, and the output voltage range is: 0 to 8 Vdc V/F CONVERTER: V/F conversion the input voltage range is: 0 to 8 Vdc, and the output frequency range is: 0 to 8 kHz F/V CONVERTER: F/V conversion the input frequency range is: 0 to 8 kHz, and the output voltage range is: 0 to 8 Vdc Necessary instruments: - Multimeter - Dual-trace oscilloscope REFERENCE GENERATOR: it outputs the regulated voltage +VREF: +8 Vdc, starting from the voltage of +12 Vdc. MCM7A:Ī20.2 DESCRIPTION of the MODULE The module MCM7A (fig. _ _ _Ī20.1 IDENTIFYING the COMPONENTS The educational system for the study of V/I, I/V,V/F, F/V Converters (fig. Several possible answers are suggested to each question, but only one is correct. The lessons described in this handbook include some “MULTIPLECHOICE” questions (quizzes). #IC1A OP AMP WINDOWS#Windows XP or higher version Module holder mod. #IC1A OP AMP SOFTWARE#SIS3-U/EV or mod.SIS3/EV or mod.SIS4-P/EV with software CBT Personal Computer with USB ports and O.S. Testing module mod.MCM7A/EV Power supply mod. NECESSARY EQUIPMENT (Lessons where Module and Software CBT are used) NECESSARY EQUIPMENT (Lessons where the only Module is used) A proper separate collection ensures that the eliminated apparatuses will undergo the necessary treatment and recycling for preventing any negative effect on the environment and on men’s health ![]() At the end of its lifetime, this equipment will be conveyed to the proper centres of separate collection of waste, or it will be returned to the tradesman when a new equivalent equipment is purchased. This symbol indicates that this equipment will be disposed of separately from the other wastes. The manufacturer cannot be held responsible for any damage due to illegitimate, wrong or unreasonable use. Any other use is illegitimate and therefore dangerous. as educational equipment, and it must be used under the direct supervision of expert personnel. This equipment must be employed only for the use it has been conceived, i.e. Before powering the module with the supply voltage of ☑2 V, make sure that the power leads are connected correctly with the power supply. In particular, check that the module is integral and shows no visible damage. After the packaging has been removed, set all accessories in order so that they are not lost. Keep this handbook at hand for any further help. Lesson A24: DESCRIPTION of V/F and FV CONVERTERSĪ24.1 Description of the V/F Converter A24.2 Calibrating the V/F Converter A24.3 Description of the F/V Converter A24.4 Calibrating the F/V Converter A24.5 Exercises VOLUME 2/2: OPERATIONAL HANDBOOK 1. Introduction V/F Converters F/V Converters Characteristics of V/F Converters Characteristics of F/V Converters Exercises Lesson A22: DESCRIPTION of V/I and I/V CONVERTERSĪ22.1 Description of V/I Converter A22.2 Calibrating the V/I Converter A22.3 Description of I/V Converter A22.4 Calibrating the I/V Converter A22.5 Exercises Lesson A23 F/V and V/F CONVERTERS Introduction V/I converters I/V converters Characteristics of V/I Converters Characteristics of I/V Converters Exercises MCM7A/EVĪ20.1 Identifying the components A20.2 Description of the module Lesson A21 V/I and I/V CONVERTERS ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |